Estimation of Aluminum Level in Locally Packaged Milk Powder | Author : Ahmed Abdel-Hameid Ahmed ,Enas El-Prince Mohammed, Manal Mohammed Amin, Doaa Abdel-Naser Abdel-Raheem | Abstract | Full Text | Abstract :This study was conducted to estimate Aluminum level (Al) in locally packaged milk powder, discussing its public health effect and suggesting recommendations to avoid such contamination. Therefore, fifty random samples of locally packaged milk powder were collected from different markets and pharmacies in Assiut Governorate, Egypt. These samples were digested and Al levels were estimated using HR-CS (High Resolution Continuum Source Atomic Absorption Spectrophotometer) and compared with Maximum Permissible Limit (MPL). About 96% of milk powder samples were containing Al with an average value of 0.086 mg/L and fortunately were lower than MPL. The present study revealed that milk powder contains aluminum element in variable concentrations above the toxicity levels. Therefore, to lower aluminum content, it is important to avoid the sources of contamination.
|
| Comparison of Three Techniques for Arthrocentesis of the Carpal Joint in Dromedary Camels: A Prospective Study | Author : Adel M. Badawy, Eman A. Eshra | Abstract | Full Text | Abstract :The aim of this prospective study was to determine the appropriate approaches for arthrocentesis of the carpal joint in dromedary camels and to compare between these approaches with regard to their success rate, feasibility, accuracy and ease of performance. Twenty-two cadaveric camel forelimbs obtained from 11 camel cadavers, and 4 living camels (6 joints) underwent arthrocentesis for therapeutic and diagnostic purposes, were used in this study. For studying gross anatomy of the suggested approaches, 4 forelimbs were used. For CT anatomy 3 forelimbs (one/each technique) were scanned before and after injection of iodinated contrast medium. For in-vitro evaluation of the techniques 15 forelimbs were used (5/each technique). To test the ease of performance in the living camels, arthrocentesis of 6 joints in 4 camels was performed by a single operator while the animal sited in kneeling position (3 camels) and standing position (one camel). Based on the results, there were three feasible approaches for arthrocentesis of carpal joint in camel, the dorso-medial, dorso-lateral, and the lateral approaches. The dorso-medial approach was easily performed and more accurate than the other approaches. The dorso-medial approach was successful with accuracy index of 100% after the first attempts, whilst the dorso-lateral and the lateral approaches have lower rates of success. The procedure was well tolerated in all camels.
|
| Mastitogenic Bacteria Isolated from Clinical Mastitis Cases Associated with Teat Lesions and their Antimicrobial Sensitivity | Author : Maha I. Hamed, Hanan K. Elsayed | Abstract | Full Text | Abstract :Mastitis is the most common and most expensive disease that impacts dairy farms in Egypt. In this study, we investigated bacterial mastitis cases that did not respond to antimicrobial treatment from buffaloes and cows. Milk samples (11) were collected from diseased animals (5 buffaloes and 6 cows). The samples were tested microbiologically to isolate and identify the causative bacteria and antimicrobial susceptibility. The antimicrobial sensitivity of the isolated bacteria was tested by using minimum inhibitory concentration technique according to the clinical national laboratory standards. The total number of bacterial isolates from the cases was 15 isolates. Staphylococcus aureus (S. aureus) was isolated alone in two cases (13.33% of the isolates), and S. aureus isolated in combination with Arcanobacterium pyogenes (A. pyogenes) in one case (6.67%), and S. aureus isolated in combination with both A. pyogenes and Streptococcus agalactiae (S. agalactiae) in two cases (13.33%), and Coagulase negative staphylococci (CNS) isolated alone in one case (6.67%), and CNS isolated in combination with Klebsiella pneumoniae in one case (6.67%), and A. pyogenes isolated alone in two cases (13.33%). In two cases were not able to isolate any bacterial pathogen. In terms of susceptibility to antibiotics, the isolated strains were sensitive to clindamycin with MICs ranging from 0.125 to <0.03125 µM. The same isolates exhibited medium sensitivity to gentamicin and ciprofloxacin with MICs ranging from 0.5 to 8 µM. Most S. aureus isolates were resistant to oxytetracycline with a MIC of 128 µM. Most of the isolated bacteria were resistant to polymyxin B with a MIC > 128 µM. With the exception of the A. pyogenes isolates, all the isolated bacteria were sensitive to enrofloxacin with a MIC <1 µM.
|
|
|